(Table 9, contd)
3965-6
Aftertreatment #1 Diesel Exhaust Flu-
id Control Module Power Supply #1 :
Current Above Normal
5966-6
Aftertreatment #1 DEF Control Mod-
ule Power Supply : Current Above
Normal
Troubleshooting, “DEF Control Module Power - Test”
3966-5
Aftertreatment #1 Diesel Exhaust Flu-
id Control Module Power Supply #2 :
Current Below Normal
6309-5
Aftertreatment 1 Diesel Exhaust Fluid
Control Module Power Supply 2 : Cur-
rent Below Normal
Troubleshooting, “DEF Control Module Power - Test”
3966-6
Aftertreatment #1 Diesel Exhaust Flu-
id Control Module Power Supply #2 :
Current Above Normal
6309-6
Aftertreatment 1 Diesel Exhaust Fluid
Control Module Power Supply 2 : Cur-
rent Above Normal
Troubleshooting, “DEF Control Module Power - Test”
4592-2
Aftertreatment #1 Outlet NH3 Sensor
Power Supply : Erratic, Intermittent, or
Incorrect
4380-2
Aftertreatment 1 Outlet NH3 Gas Sen-
sor Power In Range : Erratic, Intermit-
tent, or Incorrect
Troubleshooting, “Electrical Power Supply - Test”
4648-3
Aftertreatment Ambient Air Tempera-
ture Sensor : Voltage Above Normal
7441-3
Aftertreatment Ambient Air Tempera-
ture : Voltage Above Normal
Troubleshooting, “Sensor Signal (Analog, Passive) - Test”
4648-4
Aftertreatment Ambient Air Tempera-
ture Sensor : Voltage Below Normal
7441-4
Aftertreatment Ambient Air Tempera-
ture : Voltage Below Normal
Troubleshooting, “Sensor Signal (Analog, Passive) - Test”
5856-9
SAE J1939 Data Link #3 : Abnormal
Update Rate
1235-9
J1939 Network #3 : Abnormal Update
Rate
Troubleshooting, “CAN Data Link - Test”
5856-14
SAE J1939 Data Link #3 : Special
Instruction
1235-14
J1939 Network #3 : Special
Instruction
Troubleshooting, “Data Link Configuration Status - Test”
52 UENR4469-36
Diagnostic Trouble Codes
Copyright of Perkins Engine Company Limited. NOT FOR REPRINTING OR RESALE