• Parameter programming
• Copy configuration function for ECM replacement
• Data logging
• Graphs (real time)
Table 3 lists the service tools that are required in
order to use the Electronic Service Tool.
Table 3
Service Tools for the Use of the Electronic Service
Tool
Part Number
Description
-
(1)
Single Use Program License
-
(1)
Data Subscription for All Engines
27610164
27610401
TIPSS Adapter Kit (Electronic Service Tool to
the ECM interface)
or
Perkins CA3 Kit
(1)
Refer to Perkins Engine Company Limited.
Note: For more information on the Electronic Service
Tool and the PC requirements, refer to the
documentation that accompanies the software for the
Electronic Service Tool.
Connecting the Electronic Service Tool
and the TIPSS Adapter
Illustration 2 g01121866
(1) Personal Computer (PC)
(2) Adapter Cable (Computer Serial Port)
(3) TIPSS adapter
(4) Adapter Cable Assembly
Note: Items (2), (3) and (4) are part of the TIPSS
adapter kit.
Use the following procedure in order to connect the
Electronic Service Tool and the TIPSS Adapter.
1. Turn the keyswitch to the OFF position.
2. Connect cable (2) between the “COMPUTER” end
of TIPSS adapter (3) and the RS232 serial port of
PC (1).
Note: The Adapter Cable Assembly (4) is required to
connect to the USB port on computers that are not
equipped with an RS232 serial port.
3. Connect cable (4) between the “DATA LINK” end
of TIPSS adapter (3) and the service tool
connector.