General information
permaPRO/PROCLINEisbasedonthefunctionofpermaPRO/PROCLINE.
ThegeneralfunctionofpermaPRO/PROChasnotbeenchanged.
ThesepermaPRO/PROCLINEOperatingInstructionsmustalwaysbeusedtogetherwiththeOperating
InstructionsofpermaPRO/PROC.
Function Indication on the Display
(seeoperatinginstructionspermaPRO/PROCchapter5.2)
Lubricationsystemturnedoff(OFF)
Lubricationsystemturnedon(ON)
Differences perma PRO / PRO C LINE (compared to perma PRO / PRO C)
Thepausetimebetweentwodischargesandthedischargeamountsfrom1to9strokescanbeprogrammed
for each individual outlet.
Aftereachpausetime,thesystemwillconductadischargewithasmanystrokesasprogrammedforthisoutlet.
Thefollowingsettingsanddisplaysarenew(operatinginstructionspermaPRO/PROCchapter6.8):
Numberofstrokesperdischarge(1stroke=0.5cm
3
)
Pausetimeindaysbetweendischarges
Displayofdischargetimeremaining
Thechartonthefollowingpagewillassistwithsettings.
Total discharge period
Thelongestdischargeperiodthatthesystemcanbeprogrammedforis24 months(inordertostaywithinthe
maximumlubricantservicelife).
Thesystemcalculatesthetotaldischargeperiodbasedonthenumberofstrokesprogrammedandthepause
timeforeachoutlet.Thesystemperformsthiscalculationwhentheuserentersandsavesthepausetime.If,
atthistime,thesystemrecognisesthatthemax.dischargeperiodof24monthswillbeexceeded,thedisplay
showserror forabout3seconds.Thenthesystemwillreturntothelastcongurationstep=programmed
strokesperdischargefortheoutletthatwasprogrammedlast.Theusermustnoweitherincreasethelubricant
amountorreducethepausetime.
88
Outlets
1
3
2
4
5
6
Days
Weeks
Months
%Vol.
LC2500LC2500
Confi g.
TimeTime PIN
88
Outlets
1
3
2
4
5
6
Days
Weeks
Months
%Vol.
LC2500LC2500
Confi g.
TimeTime PIN
Time
Outlets
1
3
2
4
5
6
Weeks
LC 500
Translation of the Original Operating Instructions
perma PRO / PRO LINE C 250 / 500
Display shows „remaining
discharge period“

Table of Contents

Other manuals for Perma PRO 500

Related product manuals