1 Introduction and Basic Operation
14
Using the Main Setup Menu
In addition to the hardkeys and SmartKeys for the most needed functions, the Main Setup menu gets
you to all settings that can be adjusted for the respective device. Select the
Main Setup SmartKey to get
to the
Main Setup menu (shown below for an SpO
2
Cableless Measurement Device).
Switching the Devices Off
To switch off a device manually, select the Device Off SmartKey, then Confirm.
If you keep
Device Off pressed for more than two seconds, you can choose between Device Off or
Power Off.
Device Off means that the display is switched off and the measurements are disabled. Use this
option if your device is not used temporarily. Press any hardkey to turn the device on again.
Power Off means that the device is switched off completely and can only be switched on again by
putting it on a charger. Use this option when the device is not used for a longer time or prepared
for storage or shipping.
When an IntelliVue Cableless Measurement Device is not operated, it will automatically switch off the
screen lighting after a short time. A little later the low-activity screen will be displayed.
Operating Modes
Your device has four operating modes. Some are passcode protected.
Monitoring Mode: This is the normal, every day working mode that you use for making
measurements. You can change elements such as measurement modes, patient category and so
forth. When you remove the patient from the device, these elements return to their default values.
Changes can be stored permanently only in Configuration Mode. You may see items, such as some
menu options, that are visible but 'grayed out' so that you can neither select nor change them.
These are present for your information only and can be changed only in Configuration Mode.
Demonstration Mode: Passcode protected, this is for demonstration purposes only. You must
not change into Demonstration Mode during monitoring.
Configuration Mode: Passcode protected, this mode is for personnel trained in configuration
tasks. These tasks are described in the Configuration Guide. During installation the Cableless
Main Setup
SpO
INOPs
Patient
Equipment
User Interface
Device Off
Profiles
Operating Modes
Date, Time
Battery
Revisions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips IntelliVue CL SpO2 and is the answer not in the manual?