Service 29
8 Service
Cleaning
Instructions for cleaning!
Use a soft, lint-free cloth. Never use liq-
uid or easily flammable cleansers
(s
prays, abrasives, polishes, alcohol,
etc.). Do not allow any moisture to
reach the interior of the device. Do not
spray the device with any cleaning flu-
ids.
Wipe over the surfaces gently. Be care-
ful that you do not scratch the surfaces.
Cleaning the lens
Use a brush or lens cleaning paper for cleaning
the lens of the projector.
Do not use any liquid cleaning agents!
Do not use any liquid cleaning agents
for cleaning the lens, to avoid damaging
the coating film on the lens.
Replacing the lamp
The UHP lamp lasts up to 10,000 hours. UHP
lamps are maturing during their life time, so a
loss in brightness is a normal aging process. We
recommend to change the UHP lamp after
4,500 – 10,000 hours depending which lamp
mode is used. You can check the elapsed lamp
time in the UI menu Information – lamp hour.
The lamp is a consumable item and can be
ordered by X-GEM service hotline or on the
Philips homepage.
Do not operate the lamp beyond the
rated lamp life. Excessive operation of
lamps could cause a lamp to break on
rare occasions.
Instructions for cleaning!
The lamp becomes extremely hot dur-
ing operation. Allow the device to cool
fo
r approximately 45 minutes prior to
removing the lamp.
Turn off the projector and disconnect the device
from the power outlet.
1 Loos
en the two screws that secure the lamp
cover on the side of the projector until the
lamp cover loosens.
2 Remove the lamp cover from the projector.
DANGER!
DANGER!
CAUTION!
DANGER!
To reduce the risk of electrical
shock, always turn the projector off
and disconnect the power cable
before changing the lamp.
To reduce the risk of severe burns,
allow the projector to cool for at
least 45 minutes before replacing
the lamp.
To reduce the risk of injuries to fin-
gers and damage to internal com-
ponents, use caution when remov-
ing lamp glass that has shattered
into sharp pieces.
To reduce the risk of injuries to fin-
gers and/or compromising image
quality by touching the lens, do not
touch the empty lamp compart-
ment when the lamp is removed.
This lamp contains mercury. Con-
sult your local hazardous waste
regulations to dispose of this lamp
in a proper manner.