English
23
STARTUP
Action Function Display
Hold the on/off key
down for several
seconds
A
cycle starts with three phases which take
the stove into the normal operating mode:
•
CONTROL first 20 seconds
The extractor fan activates for a few seconds.
• START PHASE I
The fuel-loading chute is activated and starts to
feed pellets into the burner (the LED on the
display lights up at fixed time intervals).
The pilot light ignites (the LED on the display
lights up).
The extractor fan starts up.
•
START PHASE II
If the lighter has triggered the combustion process, the
fuel-loading auger slows down to allow a period of
stabilisation and correct combustion of the pellets in the
subsequent normal operating mode.
If during the startup phase the sensor on the flue gas
outlet shows a rise in temperature (sign that the
combustion process is underway), the stove is
considered to be lit and goes into the normal operating
mode.
If during the startup phase the sensor on the flue gas
outlet does NOT show a rise in temperature (sign that the
combustion process is not underway), the stove should
be considered off; a new ignition cycle will begin
automatically and the three preceding phases will be
repeated in succession.
1
FAILED IGNITION
Action Function Display
A second failed ignition is indicated on the display
in the STOVE STATUS function by the readout “NO
LIT” as well as the smoke sensor temperature,
see “PROGRAMMING” paragraph. In addition a
beep is emitted once every 5 seconds. This safety
device is activated if the pellets do not ignite, if the
pellet hopper is empty or if the temperature fails
to rise.
NO
LIT