English
38
PELLET HOPPER AND STOVE HOUSING TEMPERATURE
Sensor Description Display
Thermostat 1 with
manual reset
Located on the pellet hopper, its function is to
p
revent excessive temperature ranges.
WHEN ACTIVATED
If the pellet hopper temperature reaches critical
levels, the thermostat cuts off the power supply to
the fuel-loading auger, thereby stopping the
supply of pellets to the grate and starting the
stove shutdown process.
- The readout ALC appears in the STOVE STATUS
mode.
- After approx. 60 seconds the alarm sounds (if
activated).
Thermostat 2 with
manual reset
Located on the stove housing, its function is to
check the temperature inside the stove and to
ensure that the stove structure and operating
mechanisms are not damaged.
WHEN ACTIVATED
If the stove temperature reaches critical levels, the
thermostat will cut off the power supply to the
fuel-loading auger, thereby stopping the supply of
pellets to the grate and starting the stove
shutdown process.
- The readout ALC appears in the STOVE STATUS
mode.
- After approx. 60 seconds the alarm sounds (if
activated).
WHAT TO DO IN BOTH CASES
- Shut down the stove by holding the ON/OFF key down for several seconds
- The alarm will stop.
- Wait until combustion of any pellets remaining in the grate has finished.
Before resetting the safety devices, make sure the stove has shut down and is completely cold, then proceed as
follows:
- unscrew the two caps at the bottom left of the stove rear panel;
- one at a time, press the two small buttons. If necessary use a slotted-head screwdriver and apply light pressure;
- replace the two caps;
- after having cleaned the grate, restart the stove by pressing the ON/OFF key (4). (The readout THERMAL CUTOUT
must no longer appear on the display. If this is not the case repeat the process described above.)
With reference to standard EN 60335-1, a Piazzetta After-Sales Service Centre or an authorised person must
be contacted after two resets.
DT2040053-00
SAFE TY
THERMAL