Page #110 background image
SNMP Monitoring
Planar UltraRes User Manual 110
SNMP Monitoring
The current settings and status of UltraRes units can be remotely monitored using
SNMP (Simple Network Management Protocol), if the SNMP option is enabled
through the web browser settings. The MIB (Management Information Base) used for
all Planar display products is available by electronic distribution in the file PLANAR-
DISPLAY-MIB.txt. The table below shows the objects that can be monitored – all
Planar SNMP objects are read-only, and no traps are used. The default read-only
community string for all Planar SNMP objects is “public”. Once the PLANAR-DISPLAY-
MIB is loaded in your SNMP manager, you can walk all the available objects from the
top-level object PlanarSystems(1.3.6.1.4.1.19125) or its sub-object
PlanarDisplayProduct(1).
Most object values are integer type, except where noted. Generally, for integer types,
the value -1 is returned if there is any internal system or communication error, and
normal return values are zero or positive integers.
Object Name Description Value
plnrModel
Model name (string) UltraRes
plnrSWPart
Part number (string) for the
Remote Monitoring software
010-01412
plnrSN1
Serial number (string)
plnrVersion1 SNMP agent version (string)
plnrVersion2 Firmware version (string) See RS232 code “IFV
plnrVersion3-6
FPGA 1-4 version (string) See RS232 code “IF1” through “IF4”
plnrDisplayStatus
General display status 0 = Error
1 = OK
-1 = N/A
plnrPowerStatus
Power status information 0 = Power off or error
1 = OK
-1 = N/A
plnrDisplayBacklight
Backlight value 1-15. See RS232 code “BKL
plnrDisplayColorSpace
User-selected color space 0-4. See RS232 code CLS”
plnrInputSelect
User-selected input source 0-7. See RS232 code “INS
plnrInputStatus
Input source status 0 = source absent
1 = source present
plnrInputHResolution
Horizontal resolution Pixels
plnrInputVResolution
Vertical resolution Pixels
plnrInputVRefresh
Vertical refresh rate Hz x 100
plnrInputPixelClock
Dot clock value MHz x 100
plnrTemp1
Internal temperature sensor
value
Degrees C. See RS232 code “ITS”

Table of Contents

Other manuals for Planar UltraRes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planar UltraRes and is the answer not in the manual?

Planar UltraRes Specifications

General IconGeneral
BrandPlanar
ModelUltraRes
CategoryMonitor
LanguageEnglish

Related product manuals