Point Grey Flea3 GigE Technical Reference E Control and Status Registers
Field Bit Description Frame-Specific Information
Insert_Info
[22]
Display image-specific information
0: Off 1: On
Region of Interest (ROI) position (See page 79)
[23] GPIO Pin State
[24] Strobe Pattern Counter
[25] Frame Counter
[26] White Balance CSR
[27] Exposure CSR
[28] Brightness CSR
[29] Shutter Value
[30] Gain CSR
[31] Timestamp (See page 78)
E.11 INITIALIZE: 000h
Offset Name Field Bit Description
000h INITIALIZE
Initialize [0]
If this bit is set to 1, the camera will reset to its initial state and default settings.
This bit is self-cleared.
[1-31] Reserved
Format:
E.12 TIME_FROM_INITIALIZE: 12E0h
Field Bit Description
Presence_Inq [0]
Presence of this feature
0: Not Available, 1: Available
Time_From_Init [1-31] Time in seconds since the camera was initialized.
Format:
E.13 LINK_UP_TIME: 12E4h
Field Bit Description
Presence_Inq [0]
Presence of this feature
0: Not Available, 1: Available
Time_From_Reset [1-31] Time in seconds since the camera detected a re-connection.
Format: