Point Grey Flea3 GigE Technical Reference 6 Input/Output Control
6.3 GenICam Digital Input/Output Control
Name Display Name Description Value
LineSelector + Line Selector
Selects the physical line (or GPIO pin) of the
external device connector to configure.
Line 0
Line 1
Line 2
Line 3
LineMode Line Mode
Controls whether the physical line is used to Input
or Output a signal. Choices are dependent on which
line is selected.
Input
Trigger
Strobe
Output
LineSource Line Source
Selects which input or output signal to output on
the selected line. Line Mode must be Output.
Exposure Active
ExternalTrigger Active
LineInverter Line Inverter
Controls the invertion of the signal of the selected
input or output line
True
False
StrobeEnabled Strobe Enabled Enables/disables strobe
True
False
UserOutputValue User Output Value Sets the value of the user output selector
True = High
False = Low
LineDebounceTime Line Debounce Time
Sets the value of the selected line debouncer time
in microseconds
LineStatus Line Status
Returns the current status of the selected input or
output line
True = High
False = Low
LineStatusAll Line Status All
Returns the current status of all available line
signals at time of polling in a single bitfield
Revised 10/29/2013