STARTER SOLENOID BENCH TEST
Test the start solenoid by powering the solenoid using
battery voltage for a maximum of 5 seconds. With the
solenoid energized, there should be continuity between
terminals (A) and (B). If there is no continuity or high
resistance, replace the starter solenoid.