This command is a boolean command. See Section 6.1 for more information on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
T01AHLD1
Enable loop drop based auto hangup mode.
T01AHLD1
T01AHLD0
Disable loop drop based auto hangup mode.
T01AHLD0
T01AHLD2
Toggle loop drop based auto hangup mode.
T01AHLDx, where x is 0 or 1 depending on
the current state of the loop drop based auto
hangup mode.
T01AHLD?
Query auto hangup mode.
T01AHLDx, where x is 0 or 1 depending on
the current state of the loop drop based auto
hangup mode.
8.9. AMNOMAT -- Select NOM Attenuation on Each Output
This command enables, disables, or queries NOM attenuation for the specified output . (A, B, T). NOM
attenuation is calculated as 10*log(Number of Open Microphones).
Remember that even though there are no microphones on this device, other microphones can be
brought in via the W, X, Y, and Z busses. These signals will have NOM information carried with them
from the other devices, which is why NOM attenuation is provided at the outputs.
This command is a channel boolean command. See
Section 6.3 and Section 6.1 for more information on
this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
T01AMNOMATA1
Enable NOM attenuation on
output A.
T01AMNOMATA1
T01AMNOMATA0
Disable NOM attenuation on
output A.
T01AMNOMATA0
T01AMNOMATB2
Toggle NOM attenuation status on
output B.
T01AMNOMATBx, where x is either 0 or 1
depending on the current mute status of NOM
attenuation on the ouptut.
T01AMNOMATB?
Query NOM attenuation status of
output B.
T01AMNOMATBx, where x is either 0 or 1
depending on the current NOM attenuation
status of the output.
T01AMNOMAT*1
Enable NOM attenuation on all
outputs (A, B).
T01AMNOMAT*11
T01AMNOMAT*0
Disable NOM attenuation on all
outputs (A, B).
T01AMNOMAT*00

Table of Contents

Other manuals for Polycom Vortex EF2201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2201 and is the answer not in the manual?

Polycom Vortex EF2201 Specifications

General IconGeneral
Rack capacity1U
Frequency range250 - 3600 Hz
Cancellation span32 ms
Echo cancellation60 dB
RS-232 ports1
Modem (RJ-11) ports2
Input voltage110 - 240 V
Input frequency47/63 Hz
Power consumption (typical)15 W
Nominal input level-66 dB
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm