T01BROAD2:ATDT4048921180
Sends the string ATDT4048921180 out the RS-
232 port.
T01BROAD2
8.15. BROADA -- Broadcast Commands to Other Connected
Devices
This command is used to broadcast commands to other connected Polycom devices via the EF Bus
and/or ASPI Bus. For example, the command ' T01BROADA:B02PHONE1' would cause device ID 1 to
send a command to the EF2241 at device ID 2 to tell it to take its phone off-hook. The EF2241 at
device ID 2 would respond by taking its device off-hook and sending an acknowledgement.
This command is usually used in macros when one needs to have a macro on one device trigger an
action on another device.
Example Description Status Message
T01BROADA:B02PHONE1
Sends the command B02PHONE2
over the digital bus.
T01BROADA
B02PHONE1, this second status
message is from the EF2241 at
device ID 2 when it takes its phone
off hook.
8.16. COUNTRY -- Specify Country Definitions for Phone
Interface
This command is used to set or query the country that the Vortex is configured for operation in. The
country setting affects parameters associated with the phone interface including transmit and receive
impedances, flash hook timing, timing thresholds for detecting hangup based on loop current drop,
timing thresholds for detecting incoming rings, and outgoing DTMF levels.
The following table lists the numeric values for this command and the associated countries.
Command Value Country
0
Undefined
1
USA
More countries will be added as the Vortex is approved for operation in other countries.
This command is an integer command. See
Section 6.2 for more information on this type of command.
The minimum and maximum values for this command are 0 and 1, respectively.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.

Table of Contents

Other manuals for Polycom Vortex EF2201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2201 and is the answer not in the manual?

Polycom Vortex EF2201 Specifications

General IconGeneral
Rack capacity1U
Frequency range250 - 3600 Hz
Cancellation span32 ms
Echo cancellation60 dB
RS-232 ports1
Modem (RJ-11) ports2
Input voltage110 - 240 V
Input frequency47/63 Hz
Power consumption (typical)15 W
Nominal input level-66 dB
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm