Page #78 background imageLoading...
Page #78 background image
has been previously defined via the PRESETW command. If the specified preset is empty, then an error
condition of ERROR#070 will be returned. If one or more of the commands in the preset generated
errors, then an error condition of ERROR#072 will be returned.
When the PRESETQ command executes, status messages for all of the commands in the preset will not
be generated. The PRESETQ command is provided so that a control system can execute a preset and
not generated heavy data traffic from the resulting status messages. Of course, this assumes that the
control system is not interested in any of the acknowledgements. The
PRESETX command can be used
to execute the preset without suppressing the status messages.
Example Description Status Message
T01PRESETQ18
Execute preset number 18 without generating any status
messages.
T01PRESETQ18
8.98. PRESETW -- Save a Preset
This command writes the current settings of the device into the user preset with the specified number.
Since the factory presets (0 - 15) are read-only, an ERROR#071 will be generated if they are specified
in the PRESETW command.
Once a preset it saved, it can be recalled via the PRESETX and PRESETQ commands. The preset can
also be set to be executed automatically at power-up via the
PRESETP command.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example Description Status Message
T01PRESETW18
Save the current device settings as preset 18.
T01PRESETW18
8.99. PRESETX -- Execute a Preset
This command executes the preset corresponding to the specified number, which must be between 0
and 47. The preset must either be a pre-defined factory preset (0 - 15) or a user preset (16 - 47) that
has been previously defined via the
PRESETW command. If the specified preset is empty, then an error
condition of ERROR#070 will be returned. If one or more of the commands in the preset generated
errors, then an error condition of ERROR#072 will be returned.
When the PRESETX command executes, status messages for all of the commands in the preset will be
generated (unless
acknowledgement mode is turned off). The status messages can be suppressed by
using the
PRESETQ command, which is exactly the same as the PRESETX command except that status
messages are suppressed.
Example Description Status Message

Table of Contents

Other manuals for Polycom Vortex EF2201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2201 and is the answer not in the manual?

Polycom Vortex EF2201 Specifications

General IconGeneral
Rack capacity1U
Frequency range250 - 3600 Hz
Cancellation span32 ms
Echo cancellation60 dB
RS-232 ports1
Modem (RJ-11) ports2
Input voltage110 - 240 V
Input frequency47/63 Hz
Power consumption (typical)15 W
Nominal input level-66 dB
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm