T01MINI?
Query enabled state of modem initialization 
string.
T01MINIx, where x is 0 or 1 depending 
on the current enabled state of the 
modem initialization string. 
8.69. MINISTR -- Set Modem Initialization String
This command is used to set or query the modem initialization string. The string can be a maximum of 
32 characters long. The recommended modem initialization string for the Vortex is: 
ATF1E0&B1S0=2 
This can be set via the following command. 
T01MINISTRATF1E0&B1S0=2 
Whether or not the modem initialization string is sent at power-up is controlled via the 
MINI command. 
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved 
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned. 
Example Description Status Message
T01MINISTRATF1E0&B1S0=2
Set modem initialization 
string to 
ATF1E0&B1S0=2. 
T01MINISTRATF1E0&B1S0=2
T01MINISTR?
Query current modem 
initialization string. 
T01MINISTR<string>, where <string> 
is the current modem initialization string. If 
this command was sent after the above 
example, then the status message would 
be T01MINISTRATF1E0&B1S0=2. 
8.70. MMUTE -- Mute Crosspoint in Main Matrix or Submatrix
This command sets or queries the mute status of one or more crosspoints in either the main matrix or 
one of the EF Bus submatrices. 
This command is a matrix boolean command. See 
Section 6.4 and Section 6.1 for more information on 
this type of command. 
This command is saved to non-volatile memory only as part of a preset. The state of this command will 
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset. 
Example Description Status Message