Toggle hook status of phone interface. If the
phone was off-hook, then this command puts it
on-hook. If the phone was on-hook, then this
command takes it off-hook.
, where x is either 0 or 1 depending on
the current hook status of the phone
interface.
Query the hook status of phone interface.
, where x is either 0 or 1 depending on
the current hook status of the phone
interface.
8.93. PING -- See Which Devices Are Present
When any Vortex device receives this command, it responds with a PONG status message. This is
typically used by the host program to determine the types and IDs of all linked devices. When used in
this manner, wildcard characters are usually given for the device type and ID so that all connected
devices will respond.
In the following example, it is assumed that there are two EF2280's (device IDs 0 and 1), two EF2241's
(device IDs 2 and 3), two EF2211's (device IDs 4 and 5), two EF2210's (device ID's 6 and 7), and two
EF2201's (device ID's 0 and 1) linked together via EF Bus.
Example Description Status Message
***PING
Ping all connected device to determine the number, type, and ID of the
connected devices.
F00PONG
F01PONG
B02PONG
B03PONG
S04PONG
S05PONG
Q06PONG
Q07PONG
T00PONG
T01PONG
8.94. PRESETK -- Delete One or All Presets
This command kills (deletes) the specified preset. If a wildcard character (*) is used to specify the
preset, then all presets are deleted.
If an attempt is made to delete one of the factory presets (in the range 0-15), the PRESETK command
will fail and generate an ERROR#071. This is because the factory presets are read-only, thus the cannot
be changed or deleted.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.

Table of Contents

Other manuals for Polycom Vortex EF2201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2201 and is the answer not in the manual?

Polycom Vortex EF2201 Specifications

General IconGeneral
Rack capacity1U
Frequency range250 - 3600 Hz
Cancellation span32 ms
Echo cancellation60 dB
RS-232 ports1
Modem (RJ-11) ports2
Input voltage110 - 240 V
Input frequency47/63 Hz
Power consumption (typical)15 W
Nominal input level-66 dB
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm