EasyManua.ls Logo

Polycom Vortex EF2201 - METER - Select which Signal is Displayed on the Front Panel LED Meter; MGAIN - Set Crosspoint Gains in Main Matrix or Submatrix

Polycom Vortex EF2201
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Panel LED Meter
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
T01METERIT
Set front panel LED meter to display the
signal on input T.
T01METERIT
T01METER?
Query which signal the front panel LED
meter is currently set to monitor.
T01METERx, where x is the label
corresponding to the signal currently being
monitored. If this command was sent after
the first example given above, the response
would be T01METERIT.
8.67. MGAIN -- Set Crosspoint Gains in Main Matrix or
Submatrix
This command sets or queries one or more crosspoint gains in either the main matrix or one of the EF
Bus submatrices.
This command is a matrix integer command. See
Section 6.4 and Section 6.2 for more information on
this type of command. The minimum and maximum values for this command are -100 and 20,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
T01MGAINT,P,-3
Set gain from input T
(telephone) to P (P-Bus) to
-3 dB.
T01MGAINT,P,-3
T01MGAINT,P,>6
Increase gain from input T
(telephone) to output P (P-
Bus) by 6 dB.
T01MGAINT,P,x where x is the new value of
the crosspoint gain. If the crosspoint gain was
set to -3 dB before this command, then the
status message would be T01MGAINT,P,3.
T01MGAINT,P,?
Query gain from input T to
P Bus output.
T01MGAINT,P,x, where x is the current value
of the crosspoint gain. If the crosspoint gain
was set to -12 dB before this command, then
the status message would be T01MGAINT,P,-
12.