EasyManuals Logo

Polycom Vortex EF2201 User Manual

Polycom Vortex EF2201
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example Description Status Message
T01MACROK25
Delete all the commands associated with macro number 25.
T01MACROK25
T01MACROK*
Delete all the commands associated with all 255 macros.
T01MACROK*
8.61. MACROL -- List All Commmands in a Macro
This command lists all the commands in a given macro. For example, assume that a macro has been
defined via the following command sequence.
T01MACROS112
T01MACROA112,MUTEI*0
T01MACROA112,GAINI*0
T01MACROA112,MUTEO*0
T01MACROW112
Once this macro has been defined, issuing the command:
T01MACROL112?
Will result in the following status messages:
T01MACROL112,MUTEI*0
T01MACROL112,GAINI*0
T01MACROL112,MUTEO*0
T01MACROL112
8.62. MACROQ -- Execute Macro Quietly
This command executes the macro corresponding to the specified number. The macro must have been
previously defined and stored in non-volatile memory via the
MACROS, MACROA, and MACROW
commands. If the specified macro is empty, then an error condition of ERROR#070 will be generated.
When the MACROQ command executes, status messages for all of the commands in the macro will not
be generated. The MACROQ is provided so that a control system can execute a macro and not generate
heavy data traffic from the resulting status messages. Of course, this assumes that the control system
is not interested in any of the acknowledgements. The
MACROX command can be used to execute the
macro without suppressing status messages.

Table of Contents

Other manuals for Polycom Vortex EF2201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2201 and is the answer not in the manual?

Polycom Vortex EF2201 Specifications

General IconGeneral
Rack capacity1U
Frequency range250 - 3600 Hz
Cancellation span32 ms
Echo cancellation60 dB
RS-232 ports1
Modem (RJ-11) ports2
Input voltage110 - 240 V
Input frequency47/63 Hz
Power consumption (typical)15 W
Nominal input level-66 dB
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm