EasyManua.ls Logo

Polysoude PS 254 - Page 60

Default Icon
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAN. PS 254 EN – Ind. 2 59
! Regulation of the measured current
voltage
The adjustment of the measured current
voltage is done on the card 217 00 636 after a
correct setup of the inverter unit. In order to
verify the supplied current, you can insert a
shunt between the power source and the torch.
A Connect a voltmeter between the test
points TP3 (0 V) and TP1.
B Connect a torch capable of supporting
200 A.
C Start a "with arc" cycle without
pulsation, with a current of 200 A. The
value read must be 4 V. If not, adjust it
with the potentiometer T3.
D Start another cycle with a current of 10
A. The value read must be 0.2 V. If
not, adjust it with the potentiometer T4.
E Repeat operations C and D until the
setup is correct.
Fig. 4.4: Potentiometer for adjusting the current voltage