Poseidon SE7EN+ User Manual Appendix 3 Page 109
General alert
Figure 3-9. General alert.
The General alert symbol located in the Alarm
Signal Area will ash in synchrony with any
other parameter(s) on the screen that is/are
inappropriate or out of acceptable range. This
signal is intended to catch the diver’s atten-
tion, and prompt the diver to scan the other
elements on the screen to see which value(s)
is/are also ashing. As long as one of the other
displayed values on the Primary Display is
ashing, the General Alert symbol will also
ash.
Electronics alert
Figure 3-10. Electronics alert.
The Electronics alert symbol indicates that a
problem has been detected with the electron-
ics, such as a cable failure or electronics
failure in one of the CAN units.
The specic cause is recorded in the logged
data. If the Electronics alert symbol is shown,
ABORT the dive or DO NOT DIVE.
Decompression ceiling alert
Figure 3 -11. Decompression ceiling alert.
The Decompression ceiling alert symbol will
ash when the diver has incurred a decom-
pression obligation. The current decompres-
sion stop is displayed in a text message.
With the 40m recreational battery installed the
Poseidon SE7EN+ is not intended for decom-
pression diving, so the dive should be termi-
nated whenever this icon is displayed. The
diver should ascend towards the surface at a
slow and controlled rate, watching the Primary
Display for the Stop Alert and additional
decompression information (see below).
Stop alert
Figure 3-12b. Stop alert.
The Stop alert symbol located in the Alarm
Signal Area is displayed in one of two circum-
stances: either the diver is ascending too
rapidly, or the diver has reached the decom-
pression stop depth (“ceiling”). In either case,
the appropriate response is to immediately
stop ascending, and the diver should maintain
the current depth until the symbol
disappears.
IMPORTANT:
It is the sole responsibility of each and every Poseidon SE7EN+
diver to understand all of the alarm systems and conditions,
monitor them throughout every dive, and respond appropriately
to any alert status.
In the unlikely event that a diver incurs a
decompression obligation (i.e., the
Decompression Ceiling Alert is displayed),
and the diver then ascends above the depth
at which the Decompression Stop Alert is
displayed, the Descend arrow will ash. In
this situation, simply descend gradually until
the Descend arrow no longer ashes, and
remain at that depth until the Decompression
Stop Alert no longer displays.
Descend arrow
Figure 3-12a. Descend arrow