Chapter 5 Function parameter
28
No.
Code
Parameter name
Setting range
Factory
default
Change
Reference
page
(returns to the center
frequency)
22: Torque control
prohibited
23: Frequency change
settings temporarily
clear
24: Stop DC braking
25: Reserved
41.
F1.06
Terminal control
operation mode
0: Two-wire type
control 1
1: Two-wire type
control 2
2: Three-wire type
control 1
3: Three-wire type
control 2
0
55
42.
F1.07
Change rate of
terminal
UP/DOWN
frequency
increment
0.01 to 50.00Hz/s
0.50Hz/s
56
43.
F1.08
AI1 lower limit
0.00V to F1.10
0.00V
56
44.
F1.09
AI1 lower limit
setting
-100.0% to 100.0%
0.0%
56
45.
F1.10
AI1 upper limit
F1.08 to 10.00V
10.00V
56
46.
F1.11
AI1 upper limit
setting
-100.0% to 100.0%
100.0%
56
47.
F1.12
Filter time of AI1
input
0.00s to 10.00s
0.10s
56
48.
F1.13
AI2 lower limit
0.00V to F1.15
0.00V
57
49.
F1.14
AI2 lower limit
setting
-100.0% to 100.0%
0.0%
57
50.
F1.15
AI2 upper limit
F1.13 to 10.00V
10.00V
57
51.
F1.16
AI2 upper limit
setting
-100.0% to 100.0%
100.0%
57
52.
F1.17
Filter time of AI2
0.00s to 10.00s
0.10s
57