Chapter 5 Function parameter
90
Code
Parameter name
Setting range
Factory
default
Change
12: Inverter overload (E.oL2)
16: Inverter module overheating
fault (E.oH2)
17: External fault (E.SET)
18: Communication fault
(E.CE)
19: Current detection fault
(E.oCC)
20: Auto tuning fault (E.tE)
21: EEPROM operation fault
(E.EEP)
22: PID feedback disconnection
fault (E.PId)
Record the type of the last three faults of inverter, see the troubleshooting for the
details.
y1.03
Running frequency of
current fault
0.00Hz
y1.04
Output current of
current fault
0.0A
y1.05
Bus voltage of current
fault
0V
y1.06
Input terminal status of
current fault
0
y1.07
Output terminal status
of current fault
0
The status of current fault input terminal are decimal digits. Display all digital input
terminal status of the last fault, the order is:
Bit0
Bit1
Bit2
Bit3
Bit4
DI1
DI2
DI3
DI4
DI5
Bit5
Bit6
Bit7
Bit8
Bit9
Reserved
Reserved
Reserved
Reserved
Reserved
When the input terminal is ON, the corresponding bit is 1, OFF for 0. This value can be
used to understand the state of digital input signal at the sate of failure.
The status of current fault output terminal are decimal digits. Display all digital output
terminal status of the last fault, the order is:
Bit0
Bit1
Bit2
Bit3
Bit4
MO1
Reserved
Reserved
R0
Reserved
When the output terminal is ON, the corresponding bit is 1, OFF for 0. This value can
be used to understand the state of digital output signal at the sate of failure.