4. Disconnect the two brown wire input power connections (or two brown and two blue
wire connections for the 240 Vac option) on the ON/OFF SW Circuit Breaker , see
"" on page 102.
5. Remove the two #2 Phillips fasteners and remove the ON/OFF SW Circuit Breaker
. Retain part(s) and/or fastener(s) for installation.
Installation Instructions
1.
Reinstall the ON/OFF SW Circuit Breaker and secure using the two #2 Phillips
fasteners.
2. Reconnect the two brown input power wires (or two brown and two blue for the 240
Vac option) on the ON/OFF SW Circuit Breaker , see "" on page 102.
3.
Reinstall the Power Entry Assembly bracket and secure using the four #3 Phillips
fasteners. Make sure that the wire cables are not pinched or damaged during install-
ation.
4. Reinstall the hood cover, see "Hood Cover Replacement" on page 82.
5. Connect the power cord and switch the ON/OFF SW Circuit Breaker ON.
6. Do the Operation Verification tests (see "Operation Verification" on page 23) and
return to service.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 105
6 Replacement Procedures
ON/OFF Circuit Breaker Switch Replacement

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor Experience TRM631 and is the answer not in the manual?

Precor Experience TRM631 Specifications

General IconGeneral
BrandPrecor
ModelExperience TRM631
CategoryTreadmill
LanguageEnglish

Related product manuals