© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 47
Error 80, 81, 82, & 83 P30 Machine Controls Not Working
Description
This error monitors the incline (up and down), and speed (up and down)
controls of a P30 console. These switches are not traditional
mechanical switches, they are optical switches.
Error 80, P30 Lift Up Not Working
Error 81, P30 Lift Down Not Working
Error 82, P30 Speed Up Not Working
Error 83, P30 Speed Down Not Working
Possible Causes
1 Machine control interconnect cable has come unplugged from the upper
PCA.
2 Bad machine control cable.
3 Bad machine control assembly.
Possible Remedies
1 Open the P30 console to expose the circuit boards, and verify that
the machine control cable has not become unplugged from the upper
PCA.
2 Substitute a known good machine control cable.
3 Substitute a known good machine control assembly.