© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 65
Error 45 - Lift Moving in Wrong Direction
Description
The lift control system has detected that the lift is moving in the
opposite direction of the issued lift command.
Possible Causes
1 Lift Motor hysteresis.
2 Bad lower control module
Possible Remedies
1 This error would typically happen when the lift was already in
motion (typically downward) when a lift command in the opposite
direction (lift up) was issued.
Some motors exhibited a very long turnaround time and the lift
motor would still be moving in the original direction (downward)
while the control system was attempting to move the lift in the
opposite direction.
If the error 45 condition is persistent, replace the lift motor.
2 This is a very rare condition, if the lift moves in the opposite
direction of the issued lift command, replace the lower control
module.