© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 57
Figure 13: Lower Control Module - Fuse Location
Disconnect the lift motor from the lift platform. If the lift
tube or lift nut is jammed against the motor housing, rotate the
lift nut or lift tube away from the motor housing.
If the lift was jammed, please refer to step 3 before you
continue. Calibrate the lift motor per the procedure, Calibrating
the Incline Motor, and reattach the lift motor to the lift
platform or ramp.
2 The lower control module can fail in one of two modes. The lift
switch could fail in an operated (shorted) condition.