© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 74
If the feature is enabled the P80 Auto Stop sensor test will
count the number of times the magnet crosses the sensor.
o The P10, P20 and P30 consoles will display "USER DETECTED" if
motion is detected from the running deck or "NO USER DETECTED"
if no motion is detected from the running deck. If the Auto
Stop test in the P80 did not count steps or if the P10, P20 or
P30 consoles displayed "NO USER DETECTED", disconnect the Auto
Stop cable from the Auto Stop sensor and check for 5vDC between
the red and black wire.
If 5VDC is present replace the Auto Stop sensor.
5 Ensure the Auto Stop magnet and/or holder is mounted on the edge of
the running deck and visually inspect for damage. Replace if
appropriate.
6 Check the gap and alignment between the Auto Stop magnet and sensor.
The gap should be approximately 3/16 of an inch and the center
markings on the top of the magnet and sensor should be aligned. If
the gap is larger than 3/16"and/or the magnet and sensor are not
aligned, adjust the running deck to the correct alignment and gap.