TROUBLESHOOTING SECTION
Water heater
The water heater does not work after three ignition attempts.
The propane gas may be turned off or empty; check that the main valve is open.
Light a burner on the stove to release air that may be trapped in the gas system.
Turn the water heater switch to “Off and then back to “On” to make another ignition attempt.
Check whether a wire has come loose behind the water heater switch. Reconnect it as required.
There may be a spider’s nest in the burner duct outside. Blow
compressed air all around the burner vent to clear up the duct.
The water heateris not working.
Ensure that the water heater switch is in the “On” position.
Check the converter fuse.
Check the battery fuse.
Ensure that 12-volt or 120-volt power feed is available.
If the problem persists, consult a specialist.
The water heater runs for a short time but there is no hot water.
Check that there is propane gas.
Check that there is in fact water in the water heater tank.
Ensure that the bypass valve has not stayed in the “Bypass” position.