056
EQUIPMENT AND APPLIANCES
For motor defects, a green light will flash once for motor 1 and twice for motor 2. The red
light will flash two to nine times to indicate the following error codes.
2 times. Dead battery: Battery power is less than 6 volts.
3 times. Weak battery: Batterypower is less than 8 volts.
4 times. Batteryovercharged: Battery power exceeds 18 volts.
5 times. Excessive motor strength: High amperage, also indicates that one side of
the extension is off the track.
6 times. Motor short circuit: Motor wiring has short circuited.
8 times. No signal showing: The controller displays no signal.
This is usually a wiring problem.
9 times. No ground: The controller is short circuited to the ground.
This is usually a wiring problem.
Closing the extension manually
If the motorized extensionwill not move after following the stepsabove, you will have to
retract it manually.
Try to do this by following the instructions on your controller.