Index W Name Type Description
Max
Objects Attr
511Ch 1 Concentration-
controlled ope‐
ration on/off
U32 Concentration-controlled operation
on(1)/off(0)
SDO RW
511Eh 1 Duration of pri‐
ming
U16 Remaining duration of “Priming” SDO RW
5148h 1 Total operating
time
U32 Total operating time in hours (h) SDO RO
5152h 1 Calibration
factor
Float The calibration factor set in the
pump as a %
SDO RO
5153h 1 Deletable rota‐
tion counter
U32 Deletable rotation counter SDO RW
5154h 1 Deletable quan‐
tity counter
Float Deletable quantity counter SDO RW
Tab. 5: Strings
Index W Name Type Description Objects Attr
5042h 1 Identifica‐
tion_LED
U16 0 - Off SDO rw
>0 Set identi‐
fication time
(LED yellow
+red flash for
the duration)
1 is equiva‐
lent to
approx. 10
ms
5FEE 0 CANopen‐
StackRevi‐
sion
UINT32 ProMinent
CANopen-
Stack-Revi‐
sion
RO
Supplementary operating instructions for CANopen
15

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals