Q80A_8_2017 20
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 info@proteco.net - www.proteco.net
PHOTOCELLS TEST Function
If this function is enabled, the control panel performs a quick start-up test with the photocells to make
sure that they are in operation.
1 Use buttons to move inside the menu, till the display shows:
2 Press button to confirm.
3 Use buttons to select:
PHOTOCELLS TEST Function OFF
PHOTOCELLS TEST Function ON
4 Press button to go back to the top level menus,
then press button again till the display shows:
or wait the timeout (20 seconds) to exit.
REVERSING STROKE Function
For use with ELECTRIC-LOCK and MEL04 optional module only.
This setting makes the motors push in opposite direction for 1 second to help release
the electro-lock if the pins are tight in the striker plate.
1 Use buttons to move inside the menu, till the display shows:
2 Press button to confirm.
3 Use buttons to select:
REVERSING STROKE Function OFF
REVERSING STROKE Function ON
4 Press button to go back to the top level menus,
then press button again till the display shows:
or wait the timeout (20 seconds) to exit.
DECELERATION Function
This function decelerates the leafs at the end of the opening/closing cycle.
1 Use buttons to move inside the menu, till the display shows:
2 Press button to confirm.
3 Use buttons to select:
DECELERATION Function OFF
DECELERATION Function ON
4 Press button to go back to the top level menus,
then press button again till the display shows:
or wait the timeout (20 seconds) to exit.