3.Clear All Set
4.Clear Cross Set
5.Save Set Info
6.Make Default Set
7.Clear Reset and Board-Change Flag
8.Test Watchdog
9.Test EEPROM
Operate Command:1-9, Menu Display: M, Return: Q Command:
A.25.1 System Reset
In operate menu press number key 1 to reset the system:
Run this command, the device will restart and need reinput password for enter console operating.
Run this command(Y/N):
Press Y to reset (system will be repowered on) and N to cancel.
A.25.2 Mute
In operate menu press number key 2 to mute alarm sound once and there will not be any prompt.
A.25.3 Clear All Set
In operate menu press number key 3 to clear all configurations:
Run this command, the device will format all data. System will be initialized.
Run this command (Y/N):
Press Y to start initialization and N to cancel.
Note: system initialization will set all configurations in 0 status, and parts restore to factory default
value. All cross set will be cleared.
A.25.4 Clear Cross Set
In operate menu press number key 4 to clear cross set:
Run this command, the device will format all cross data. All data will be nil.
Run this command(Y/N):
Press Y to start initializing all cross connect and N to cancel.
A.25.5 Save Set Info
In operate menu press number key 5 to save all information in RAM to EEPROM.