FNFN SS23
FNNF SS25
FNNN S1FC
NFFF M
Other Reporting S1 (0000) trap if set bits in Other status
F Without ALS function
5 ALS
N With ALS function
F Enable auto negotiation function
6
Auto
negotiation
N Disable auto negotiation function
F Ethernet port rate is 100M (auto negotiation disable)
7 100M/10M
N Ethernet port rate is 10M (auto negotiation disable)
F
Ethernet port works in full duplex mode (auto
negotiation disable)
8
Full/half
duplex
N
Ethernet port works in half duplex mode (auto
negotiation disable)
F Relative E1 line works normally
1-4
1-4E1
Loop back
N Relative E1 line is doing the loop back test
F Local loop back
5
Loop back
type
N Remote loop back
SW2
6-8 Reserved Reserved
Note: F stands for OFF and N stands for ON status. Network management has higher privilege than
DIP switches except optical module type and ALS function configuration. All configuration
information is available through Hyper Terminal. Bit 1-5 of SW1 are set by default in factory
according to optical module type and other bits are all OFF.
5.22 Function of RC3000-SUB-OPT-2E1
Optical line-board can communicate with main board and its initial value can be set through DIP
switches. There are 3 groups of 8-bit DIP switches and definitions are as follows:
Switch Definition Value Explanation
FFFF S1
FFFN S2
FFNF S3
FFNN SS13
FNFF SS15
FNFN SS23
FNNF SS25
FNNN S1FC
NFFF M
SW1
1-4
Optical
module
type
Other Reporting S1 (0000) trap if set bits in Other status

Table of Contents