3. If a material reservoir is installed in the machine, pull the
reservoir out of the machine. Store the reservoir in a reservoir
box.
4. Check the calibration plate for dust, streaks, fingerprints. If
necessary, clean the plate with a microfibre cloth soaked in
isopropanol. Then clean the plate with a microfibre cloth soaked
in glass cleaner.
5. Slide the calibration plate into the machine until the stop.
6. Insert the building platform. → Chapter 8.4.2
The platform must be in the reference position.
To check the parallelism (card check) please proceed as follows:
1. Main menu: Press the 'Manual' button.
2. Press the 'Find Zero' button. The platform now moves to the zero
point. Wait until the platform stops moving.
3. Take a paper card and try to slide it under each of the four
corners of the platform.
— If you cannot push the card under any of the corners,
then the platform is sufficiently well adjusted. No further
settings are required. Run the platform back to its
original position.
— If you can slide the card under one or more corners, the
parallelism must be adjusted again.
To adjust the parallelism, please proceed as follows:
1. Identify the corners that need to be readjusted.
2. Run the platform a few centimetres upwards with the 'Move Up'
button.
3. Loosen the four (inner) fastening screws on the platform top.
4. Now turn the (outer) threaded bolts at the identified corners in
the respective direction (tighten/loosen).
5. Tighten the four fastening screws again.
6. To check the parallelism again, repeat steps 2-3.
To end the adjustment please proceed as follows:
1. If you cannot slide a paper card under the corners of the
platform, then the parallelism adjustment is sufficient.
2. Run the platform back up to its reference point.
3. Pull the calibration plate out of the machine and put it back
safely into the packaging.