12 | Initial start-up
100 / 108 80.06.070_iCombiPro-iCombiClassic_IM_en-GB
After installing the unit, affix the sticker indicating the maximum rack height at
a height of 1600 mm [63 inches] to the unit. The sticker is provided in the
starter kit.
Perform software update
NOTICE
Perform software update
Always conduct a software update for commissioning. Your unit will then
start up with the latest software version.
12.2 Perform the self-test
DANGER
Changed CO / CO
2
values after the self-test
Risk of poisoning due to excessive exhaust gas values.
n
Conduct a flue gas analysis after the selftest.
n
Set the values pursuant to the flue gas analysis provisions.
When first commissioning the unit, the selftest must be started once. During
the selftest, the unit adapts to the ambient conditions.
The selftest runs automatically. The duration depends on the unit size and is
between 45 and 65 minutes. With an UltraVent extraction hood, the self-test
is extended by approx. 20 minutes.
Preparations
n
The unit must be properly connected to water, waste water, and electricity
as described in this manual; gas models must also be connected to gas
supply and flue exhaust lines.
n
Check the side racks and the air baffle to ensure they are seated correctly.
n
The left side panel is closed.