5 | Placement
80.06.070_iCombiPro-iCombiClassic_IM_en-GB 39 / 108
n
The substructure must meet the static requirements for the weight and
dimensions of the unit. Check whether the static requirements are met.
n
The tabletop must be at least 2mm [1/8 inch] thick.
Units of unit sizes 6-2/3 to 10-2/1 can be installed directly on non-original
substructures of the unit manufacturer.
Only install the unit on substructures that are statically suitable for this purpose.
Note the unit weight (Unit weight [}16]) including the maximum load.
If the unit is built on a non-original substructure, the manufacturer’s liability shall
be voided.
5.3 Installation of standalone units
5.3.1 Installing and aligning standalone units
Lift and set up standalone unit from transport pallet
CAUTION
Risk of tipping when installing the unit
Risk of crushing if the unit tips onto persons.
n
Note the centre of mass of the unit.
n
Make sure that the unit does not tip over from the pallet during
installation.
CAUTION
Risk of injury due to the weight of the unit
Personal injury and damage to property due to tipping over of the unit
n
At least 2 people are required to set up the unit.
a The installation surface is level, clean and free of grease.
a The carrying aid is available.