11 | Exhaust gas connection on gas units
80.06.070_iCombiPro-iCombiClassic_IM_en-GB 95 / 108
n
A clearance of 400 mm [15.75 inches] must be kept between the flue pipes
of the unit and the fat filters of the exhaust hood/ventilation ceiling in order
to prevent a risk of fire in the fat filter.
n
Please note that for flue gas connection type B13 there must be a vertical
upflow section.
n
The upflow section must end 400 mm [15.75 inches] beneath the fat filter.
The unit must be installed underneath an exhaust hood or a ventilation ceil-
ing.
n
Monitor the exhaust vent to ensure that gas is only fed to the burners when
extraction is ensured.
11.4 Type B13BS exhaust gas connection
CAUTION
Incorrect function of the units when installed with non-original exhaust gas
collector with and without flow guard
Installing units with a non-original exhaust gas collector or exhaust gas
collector with flow guard may damage the unit. With B13BS, the safety
function is not available. Frequent, undesired false alarms may occur.
n
Only use original exhaust gas collectors or exhaust gas collectors with
flow guards from the manufacturer for installation.