6.9 Power ratings of different voltage types
Maximum connection voltage
n
Maximum permissible tolerance for input voltage: -15% to +10%
n
The unit can be used with frequencies of 50 Hz and 60 Hz without making
any technical modifications.
n
In the scope of DIN VDE 0100-410 or DIN VDE 0100-530, we recom-
mend 30 mA tripping current per unit.
iCombi Pro, iCombi Classic Elektrogeräte
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (1 NAC 230 V) 50/60 23.1 5.3 25 F
6-1/1 E (1 NAC 230 V) 50/60 47 10.8 50 F
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (1 NAC 240 V) 50/60 24 5.7 25 F
6-1/1 E (1 NAC 240 V) 50/60 48.8 11.7 50 F
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (1 ph 208 V) 60 27.4 5.7 30 B