10 | Gas connection for gas units
82 / 108 80.06.070_iCombiPro-iCombiClassic_IM_en-GB
10 Gas connection for gas units
This section only applies to gas units.
DANGER
Fire due to incorrect gas connection
Danger to life due to fire from an incorrect gas connection.
n
Follow local regulations of the gas supply company.
n
Check the type of gas available and the dynamic connection pressure
against the values specified on the unit.
DANGER
Risk of poisoning due to faulty gas connection
Risk of poisoning from CO and other toxic gas components
n
Do not connect the units to networks containing carbon monoxide (CO)
gases or other toxic components.
DANGER
Permissible CO/CO
2
values exceeded
Risk of poisoning due to excessive CO/CO
2
values because of incorrect
burner settings.
n
Always perform a flue gas analysis when commissioning gas units.
n
Document the flue gas values.
n
It is recommended that the installation site be equipped with a CO gas
detector.
DANGER
Increased CO values due to wrong gas type
Risk of poisoning due to connection of wrong gas type
n
Only connect the unit to the gas type stated on the unit type plate.
n
Check the type of gas available and the dynamic connection pressure
against the values specified on the unit.
n
It is recommended that the installation site be equipped with a CO gas
detector.

Table of Contents

Other manuals for Rational CombiMaster Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus and is the answer not in the manual?

Rational CombiMaster Plus Specifications

General IconGeneral
ModelCombiMaster Plus
ManufacturerRational
CategoryOven
Cooking modesSteam, Convection, Combination
Temperature range30°C to 300°C
Cleaning systemManual cleaning
Power ConsumptionVaries by model
Steam Generator OutputVaries by model
WeightVaries by model
DimensionsVaries by model
Control typeManual
Capacity10-20 levels (depending on model)

Related product manuals