12 | Initial start-up
80.06.070_iCombiPro-iCombiClassic_IM_en-GB 101 / 108
n
For the selftest, one GN container is required per fan wheel.
Insert the GN container
1. Insert one flat GN container in front of each fan wheel into the middle of the
hook ladders, with the opening facing the bottom.
>> For unit sizes 6-2/3 GN to 6-2/1 GN, there is a GN container located in
the middle of the hinged rack in front of the fan wheel.
>> For unit sizes 10-1/1 GN and 10-2/1 GN, there are 2 GN containers in the
hook ladders, one in front of each fan wheel.
>> For unit sizes 20-1/1 GN and 20-2/1 GN, there are 3 GN containers in the
mobile oven rack, one in front of each fan wheel.
Start self-test
1. Close the cooking cabinet door.
2. Start the selftest.
>> The selftest will check whether the unit is sealed. If steam emerges from the
closed cooking cabinet door during the self-test, wait until the self-test is
completed and then check the door setting.
>> The display will indicate when the selftest is complete.
NOTICE
If steam escapes from the door during the selftest, the door setting may be
incorrect. In this case, check the door setting and reset the door if necessary.
12.3 iCareSystem AutoDose
*Only iCombi Pro when ordering the option iCareSystem AutoDose. The option
must be ordered separately and is available for unit size 6-1/1 - 10-2/1.
The option is not retrofittable.
Observe the regulations for the drain connection in the chapter Drain connec-
tion (Regulations for drain connection [}77]).