9 | Drain connection
76 / 108 80.06.070_iCombiPro-iCombiClassic_IM_en-GB
9 Drain connection
9.1 Regulations for drain connection
General notes for all units
NOTICE
The drain pipe does not meet requirements
Use a drain pipe with a high temperature resistance, which corresponds at
least to a type PP pipe. Do not use a hose.
NOTICE
Incorrect installation of drain pipe
Do not solvent weld or glue the drain pipe to the unit drain.
Do not connect the drain pipe using a reducer to the unit drain.
NOTICE
Never close or cover the safety overflow
Do not reduce the safety overflow in the cross section.
The safety overflow must always be accessible and free. This is used for
ventilation and drainage as a drain.
NOTICE
Dirty and greasy waste water
Make sure that a grease trap is installed by the owner to clarify the waste
water.
n
The unit complies with all relevant regulations (SVGW, KIWA, KIWA UK).
n
The average wastewater temperature is 65°C [149°F].
n
When dimensioning the drain, ensure that the steam generator short-term
pump-off rate is 0.5 l/s [0.13 gal/s].
n
If floor drain has no odour lock, make sure a 20 mm [0.79 inch] free outlet
section is in place.
n
Each unit size can be connected to a wall drain or floor drain.
Requirements for the unit size 6-2/3 GN
We recommend integrating a siphon into the drain connection in order to op-
timise energy consumption.
n
Diameter of the unit drain: DN40mm [1.5inches]

Table of Contents

Other manuals for Rational CombiMaster Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus and is the answer not in the manual?

Rational CombiMaster Plus Specifications

General IconGeneral
ModelCombiMaster Plus
ManufacturerRational
CategoryOven
Cooking modesSteam, Convection, Combination
Temperature range30°C to 300°C
Cleaning systemManual cleaning
Power ConsumptionVaries by model
Steam Generator OutputVaries by model
WeightVaries by model
DimensionsVaries by model
Control typeManual
Capacity10-20 levels (depending on model)

Related product manuals