6 | Electrical connection
80.06.070_iCombiPro-iCombiClassic_IM_en-GB 63 / 108
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (2 AC 230 V) 50/60 23.1 5.3 25 B
6-1/1 E (2 AC 230 V) 50/60 47 10.8 50 B
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (2 AC 240 V) 50/60 24 5.7 25 B
6-1/1 E (2 AC 240 V) 50/60 48.8 11.7 50 B
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (1 ph 240 V) 50/60 24 5.7 30 B
6-1/1 E (1 ph 240 V) 50/60 45 10.8 60 B
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (3 AC 200 V) 50/60 15.9 5.3 16 B
6-1/1 E (3 AC 200 V) 50/60 29.2 10.1 32 B
6-2/1 E (3 AC 200 V) 50/60 60 20.8 63 B
10-1/1 E (3 AC 200 V) 50/60 50.5 17.5 63 B
10-2/1 E (3 AC 200 V) 50/60 99.9 34.6 100 B
20-1/1 E (3 AC 200 V) 50/60 99.6 34.5 100 B
20-2/1 E (3 AC 200 V) 50/60 181.9 63 200 B
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (3 ph 208 V) 60 15.9 5.7 20 B
6-1/1 E (3 ph 208 V) 60 30 10.8 35 B
6-2/1 E (3 ph 208 V) 60 62.2 22.4 70 B
10-1/1 E (3 ph 208 V) 60 52.5 18.9 60 B
10-2/1 E (3 ph 208 V) 60 103.8 37.4 125 B
20-1/1 E (3 ph 208 V) 60 103.3 37.2 125 B
20-2/1 E (3 ph 208 V) 60 188.5 67.9 200 B