6 | Electrical connection
80.06.070_iCombiPro-iCombiClassic_IM_en-GB 49 / 108
n
Only use power cables in accordance with the provisions of the NEC/
NEMA.
n
Only connect the unit with copper cables. The cables must comply with the
applicable regulations.
Colour coding of wires:
Note the colour coding of wires and local deviations.
Wire colour Wire function
Yellow/green Protective conductor
Blue Neutral conductor (neutral wire)
Brown, grey or black Phase L1, L2, L3
Residual current circuit breaker
All units are generally equipped with a protective conductor terminal. It may
also be necessary to include a RCD residual current circuit breaker when in-
stalling the unit to comply with country-specific standards and regulations.
Unit size 6-1/1 GN to 20-2/1 GN
Connect the unit to a residual current circuit breaker according to the table
Power ratings of different voltage types [}62].
Unit size 6-2/3 GN
Voltage forms with neutral ("NAC"): connect the unit to a residual current circuit
breaker according to the table Power ratings of different voltage types [}62].
Voltage waveforms without neutral conductor ("AC"): Connect the unit to a re-
sidual current circuit breaker in accordance with the table Power ratings of dif-
ferent voltage types [}62].
The power connection of the unit must be established so that the mains plug is
freely accessible and can be disconnected from the mains at any time.
Notes for standalone units
n
Maximum connection impedance at the grid connection point is 0.09 Ω.
n
The cross-sections of the connection lines depend on current consumption
and local regulations.
Notes for UltraVent/UltraVent Plus condensation hoods
For units with a condensation hood, both units must be disconnected from the
mains prior to servicing work.
Before you disconnect the power cord from the mains or reconnect it to the
mains, make sure that the unit is switched off to prevent the condensation hood
from running.
Notes for 6-2/3 GN units with a UltraVent/UltraVent Plus condensation hood
n
The condensation hood be connected to an electrical supply in line with ap-
plicable standards (VDE and UL/CSA NEC regulations).

Table of Contents

Other manuals for Rational CombiMaster Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus and is the answer not in the manual?

Rational CombiMaster Plus Specifications

General IconGeneral
ModelCombiMaster Plus
ManufacturerRational
CategoryOven
Cooking modesSteam, Convection, Combination
Temperature range30°C to 300°C
Cleaning systemManual cleaning
Power ConsumptionVaries by model
Steam Generator OutputVaries by model
WeightVaries by model
DimensionsVaries by model
Control typeManual
Capacity10-20 levels (depending on model)

Related product manuals