10 | Gas connection for gas units
88 / 108 80.06.070_iCombiPro-iCombiClassic_IM_en-GB
6-1/1 6-2/1 10-1/1 10-2/1 20-1/1 20-2/1
Wobbe index (MJ/
m³) Wi
74.75 74.75 74.75 74.75 74.75 74.75
Wobbe index (MJ/
m³) Ws
81.19 81.19 81.19 81.19 81.19 81.19
Max. Consumption
at rated thermal load
(at 15°C, 1013
mbar)
1.01
kg/h
2.18
kg/h
1.71
kg/h
3.11
kg/h
3.26
kg/h
6.21
kg/h
Max. Consumption
at rated thermal load
(at 15°C, 1013
mbar)
13 kW 28 kW 22 kW 40 kW 42 kW 80 kW
LPG Australia
6-1/1 6-2/1 10-1/1 10-2/1 20-1/1 20-2/1
Dynamic gas pressure
(kPa)
2.75-3.
5
2.75-3.
5
2.75-3.
5
2.75-3.
5
2.75-3.
5
2.75-3.
5
Wobbe index (MJ/
m³) Wi
74.75 74.75 74.75 74.75 74.75 74.75
Wobbe index (MJ/
m³) Ws
81.19 81.19 81.19 81.19 81.19 81.19
Max. Consumption at
rated thermal load (at
15°C, 1013 mbar)
52 MJ/
h
112
MJ/h
88 MJ/
h
160
MJ/h
168
MJ/h
320
MJ/h
Natural Gas Australia
6-1/1 6-2/1 10-1/1 10-2/1 20-1/1 20-2/1
Dynamic gas pressure
(kPa)
1.13-2.
5
1.13-2.
5
1.13-2.
5
1.13-2.
5
1.13-2.
5
1.13-2.
5
Wobbe index (MJ/
m³) Wi
45.67 45.67 45.67 45.67 45.67 45.67
Wobbe index (MJ/
m³) Ws
50.72 50.72 50.72 50.72 50.72 50.72
Max. Consumption at
rated thermal load (at
15°C, 1013 mbar)
52 MJ/
h
112
MJ/h
88 MJ/
h
160
MJ/h
168
MJ/h
320
MJ/h
Natural Gas 13A Japan
6-1/1 6-2/1 10-1/1 10-2/1 20-1/1 20-2/1
Required connection
flow pressure (mbar)
18-25 18-25 18-25 18-25 18-25 18-25

Table of Contents