Maintenance and repair
119
C
AXIS
AXIS 20.1
AXIS 20.2
2. Tighten the screw connec-
tion [1] with a torque wrench
(Tightening torque =
65 Nm).
Figure 23: Fastening the tie rod at the weigh
frame
3. Tighten the screw connec-
tion with a torque wrench
(Tightening torque =
65 Nm).
Figure 24:
Fastening the tie rod at the hopper
NOTICE
After tightening the screw connections using the torque wrench, the weighing
cells must be tared anew. Please follow the instructions in the chapter “Machine
tare" of the operator’s manual of the operating unit.