EasyManua.ls Logo

Rauch AXIS-M 20.2 EMC - C.5 Adjusting the Drop Point

Rauch AXIS-M 20.2 EMC
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and repair C
122
AXIS
AXIS 20.2
C.5 Adjusting the drop point
By altering the drop point, the working width can be accurately set and adjust-
ments to different fertiliser types can be made.
Check the setting of the drop point at the start of each working season, and during
the season if necessary (if uneven spreading is noticed).
The drop point is set using the top scale arc.
Figure 27: Checking the drop point
Checking:
1. Set the drop point to position 6.
2. Remove both outlets along with their brushes at both openings.
3. Release both plastic levers (agitator drive) and slide them downwards until
the splines of the agitator are showing.
4. Attach a suitably thin string at the rear in the direction of travel to the splines
of the agitator shafts and tauten it.
The triangular mark on the base plate must be aligned to the taut string.
If the mark is not aligned to the string, the drop point must be readjusted.
NOTICE
The drop point must be set to the same position on both sides. Therefore, al-
ways check both settings.
K
D
R
C
Q
W
EMC

Table of Contents