Maintenance and repair
153
C
AXIS
AXIS 20.1
AXIS 30.2, AXIS 40.2
2. Tighten the screw connec-
tion [1] with a torque wrench
(Tightening torque =
65 Nm).
Figure 20: Fastening the tie rod at the weigh
frame
3. Tighten the screw connec-
tion with a torque wrench
(Tightening torque =
65 Nm).
Figure 21:
Fastening the tie rod at the hopper
NOTICE
After tightening the screw connections using the torque wrench, the weighing
cells must be tared anew. Please follow the instructions in the chapter “Machine
tare" of the operator’s manual of the operating unit.