General commissioning (all machine types) 8
72
AXISAXIS
Normal spreading in or out of the headland tramline
If you continue spreading in the field after headland tramline spreading:
Move the border spreading unit TELIMAT out of the spreading area.
Figure 8.20: Normal spreading
[A] End of spreading fan when spreading in the headland tramline
[E] End of spreading fan when spreading in the field
[T] Headland tramline
[X] Working width
The metering slides open or close at different distances to the field border of the
headland when travelling backwards and forwards.
NOTICE
If you use a GPS System (e.g. QUANTRON guide) as well as the operating unit
QUANTRON-E2 and/or QUANTRON-A for operating your machine, check that
the software of the operating unit includes the OptiPoint function.
The OptiPoint function by RAUCH calculates the optimal switching-on and
switching-off point for spreading in the headline based on the settings in the
operating unit.
You can skip the information in the present paragraph since the OptiPoint
function assumes these settings.
Please observe the operator’s manual for the corresponding operating unit.
E
A
X

Table of Contents