Move the stop to the position indicator and
clamp the stop there.
Fig. 73: Move the stop
u
Remove the pin from the metering opening.
u
Loosen the screws [1] of the application
rate scale.
u
Move the entire scale such that the stop is
in precisely position 130 (position 9 for
seeds or slug pellets) on the scale curve.
w
If the slot range for the scale is
insufficient, change the distance at the
angle joint.
Fig. 74: Move the scale
u
Screw the application rate scale tight again.
u
Version Q/W
Set the stop to the maximally open position (end of the slotted hole).
Tighten the adjustment screw and additionally fix the stop with the fillister head screw.
u
Connect the metering slide and hydraulic/electronic cylinder.
Install the bolt and lock washer.
u
Version K/R:
Install the spring by hand (see Fig. 69 Remove the spring).
u
Reinstall both spreading discs.
u
Version Q/W
Readjusting the test points (see operators manual).
Adjustment is now complete. If you now disconnect the hydraulic hose from the tractor/unit, the return
spring of the single-acting hydraulic cylinder must first be released. See 9.14 Parking and unhitching
the machine
11. Maintenance and service