42
Table 12Specific protocol contents and command examples of laser
Command
Description
Command example
ABF
Aiming Beam OFF –Turn off red
Send: ‘ABF\r’
Return: ‘ABF\r’
ABN
Aiming Beam ON – Turn on red
Send: ‘ABN\r’
Return: ‘ABN\r’
DEABC
Disable External Aiming Beam Control
Send: ‘DEABC\r’
Return: ‘DEABC\r’
EEABC
Enable External Aiming Beam Control
Send: ‘EEABC\r’
Return: ‘EEABC\r’
DEC
Disable External Control
Send: ‘DEC\r’
Return: ‘DEC\r’
EEC
Enable External Control
Send: ‘EEC\r’
Return: ‘EEC\r’
DLE
Disable Hardware Emission Control
Send: ‘DLE\r’
Return: ‘DLE\r’
ELE
Enable Hardware Emission Control
Send: ‘ELE\r’
Return: ‘ELE\r’
EM
OFF
Stop Emission
Send: ‘EMOFF\r’
Return: ‘EMOFF\r’
EMON
Start Emission
Send: ‘EMON\r’
Return: ‘EMON\r’
MPWR
OFF
Main Power OFF
Send: ‘MPWROFF\r’
Return: ‘MPWROFF\r’
MPWR
ON
Main Power ON
Send: ‘MPWRON\r’
Return: ‘MPWRON\r’
SPW
Set Pulse Width
Send: ‘SPW 100\r’
Return: ‘SPW:100\r’
(Set pulse width as 100ms)
Other return values:
‘ERR: input Err\r’
(Input pulse width <0.0001)
‘ERR: Out of Range\r’
(Over maximum pulse width)
‘ERR: Duty Cycle too High\r’
‘ERR: Duty Cycle too Low\r’
‘SPW:100, Duty=100%\r’
SPRR
Set Pulse Repetition Rate
Send: ‘SPRR 1000\r’
Return: ‘SPRR:1000\r’
‘ERR: input Err\r’
‘ERR: Out of Range\r’
‘ERR: Duty Cycle too High\r’
‘ERR: Duty Cycle too Low\r’
‘SPW: 100, Duty=100%\r’

Table of Contents